R32 Inverter Heat Pump
video
R32 Inverter Heat Pump

R32 Inverter Heat Pump

R32 split type Inverter Heat Pump, we use Dc Inverter systerm which optimized energy-saving control software enables the pump to achieve maximum energy-saving operation; our R32 Inverter Heat Pump could supply max 60℃ hot water, and make house heating cooling, the working ambient temperature range is -25°C-43°C, we have exported to many Europe Countries, especially in low-temperature environments such as Eastern Europe and Northern Europe, our split inverter heat pump can be used to effectively reduce the risk of freezing.

R32 split type Inverter Heat Pump, we use Dc Inverter systerm which optimized energy-saving control software enables the pump to achieve maximum energy-saving operation; our R32 Inverter Heat Pump could supply max 60℃ hot water, and make house heating cooling, the working ambient temperature range is -25°C-43°C, we have exported to many Europe Countries, especially in low-temperature environments such as Eastern Europe and Northern Europe, our split inverter heat pump can be used to effectively reduce the risk of freezing.

 

Dc Heat Pump Parameters

K-Thermal DC Inverter air to water heat pump for Heating & Cooling & Hot Water (Split type, R32 )

Model

DCI03PS-H3DS

DCI05PS-H5DS

DCI06PS-H5DS

DCI08P-H8DS

Power supply

V/ Hz

220V/50Hz

380V/50Hz

Dry/Wet bulb: 7/6℃; Water inlet/outlet: 35/40℃

Heating capacity

kW

10.50

14.71

16.23

20.20

Input power

kW

2.15

3.13

3.51

4.33

COP

/

4.88

4.70

4.63

4.66

Dry/Wet bulb: 7/6℃; Water inlet/outlet: 45/50℃

Heating capacity

kW

10.60

14.89

15.97

20.00

Input power

kW

2.79

4.01

4.63

6.05

COP

/

3.80

3.71

3.45

3.31

Dry/Wet bulb: 7/6℃; Water inlet/outlet: 47/55℃

Heating capacity

kW

10.15

13.60

15.25

19.64

Input power

kW

3.39

4.26

5.00

6.34

COP

/

2.99

3.19

3.05

3.10

Dry/Wet bulb: -7/-8℃; Water inlet/outlet: 30/35℃

Heating capacity

kW

7.58

12.12

14.48

16.51

Input power

kW

2.32

3.66

4.52

5.25

COP

/

3.27

3.32

3.20

3.15

Dry/Wet bulb: -20/-21℃; Water inlet/outlet: 30/35℃

Heating capacity

kW

4.51

7.32

8.47

10.45

Input power

kW

2.19

3.26

3.85

4.85

COP

/

2.06

2.25

2.20

2.16

Dry/Wet bulb: 35/24℃; Water inlet/outlet: 23/18℃

Cooling capacity

kW

10.40

14.93

16.17

20.17

Input power

kW

2.35

3.51

4.10

5.03

EER

/

4.43

4.25

3.94

4.01

Dry/Wet bulb: 35/24℃; Water inlet/outlet: 12/7℃

Cooling capacity

kW

8.46

12.83

14.06

18.10

Input power

kW

2.88

4.49

4.97

6.43

EER

/

2.93

2.86

2.83

2.81

Seasonal Heating Energy Efficiency Rating

LWT at 35℃

A+++

A+++

A+++

A+++

LWT at 55℃

A++

A++

A++

A++

SCOP

LWT at 35℃

4.55

4.64

4.70

4.64

LWT at 55℃

3.55

3.58

3.65

3.43

SEER

LWT at 7℃

4.66

4.67

4.62

4.65

LWT at 18℃

6.58

6.85

6.74

6.76

Max. Current

A

14.10+13.60+13.60+13.60

30+13.60+13.60+13.60

30+13.60+13.60+13.60

15+13.60+13.60+13.60

Rated Current

A

10+13.60+13.60+13.60

14+13.60+13.60+13.60

15+13.60+13.60+13.60

8+13.60+13.60+13.60

Water pressure drop

kPa

40.00

42.00

44.00

46.00

System pressure

Mpa

1/4.15

Refrigerant

Type

R32

R32

R32

R32

Quantity

kg

2.50

2.90

3.50

4.00

GWP value

675.00

675.00

675.00

675.00

Equivalent CO2

Ton

1.69

1.96

2.36

2.70

Fan motor

Type

DC INVERTER

Quantity

1.00

2.00

2.00

2.00

Noise level(Outdoor unit)

dB(A)

57.00

62.00

62.00

68.00

Noise level(Indoor unit)

dB(A)

35.00

35.00

35.00

35.00

Waterproof level

IPX4

Refrigerant pipe between indoor and outdoor unit

Gas pipe

mm

φ15.88

φ15.88

φ15.88

φ19

Liquid pipe

mm

φ9.52

φ9.52

φ9.52

φ9.52

Water pipe connection

Inlet

mm

DN25

DN25

DN25

DN32

Outlet

mm

DN25

DN25

DN25

DN32

Outdoor unit dimensions

mm

1160x490x860

1160x490x1260

1160x490x1260

1160x490x1568

Outdoor unit pacakge dimensions

mm

1195x500x1010

1195x500x1410

1195x500x1410

1195x500x1718

Indoor unit dimensions

mm

530*770*340

530*770*340

530*770*340

530*770*340

Indoor unit pacakge dimensions

mm

570*790*400

570*790*400

570*790*400

570*790*400

Outdoor unit Net Weight

kg

60

90

100

120

Indoor unit Net Weight

kg

33.5

35

36

38

Loading(20GP/40HQ)

Pcs

32/76

21/44

21/44

21/44

The above parameters may have some differences from the final product because of products updating, so above information is not the provision of any business contract. Please refer to final product label when buy, or refer to us for any information. Our company keeps the right to interpret.

class-energy-efficiency-of-washing-machines

Heating energy efficiency level A+++ at water temperature 35 deg C.
Heating energy efficiency level A++ at water temperature 55 deg C.

R32

New R32 refrigerant, ODP = 0, GWP = 675. Working together to reduce greenhouse gas emissions.

R-C

Wifi function for our heat pumps, control your heat pump from our special designed App.

202209151337031

High precision electronic expansion valve: use electronic expansion valve for controlling, reach 500 steps adjustment, adjust super heat degrees accurately, achieve high efficiency operation system.

Built-in inverter pump:
  • Reduce installation cost and time.;
  • More flexible control;
  • Optimized energy-saving control software enables the pump to achieve maximum energy-saving operation;
  • The pressure of the pipe network is set according to the actual water consumption, and the water output of the pump is automatically controlled, which reduces the phenomenon of water leakage;
  • The soft start of the pump is realized by the frequency converter, so that the pump can realize the non-impact switching from the power frequency to the variable frequency, so as to prevent the impact of the pipe network, avoid the pressure of the pipe network exceeding the limit and the pipeline rupture.
WILO

With high quality expansion tank inside, save installation costs and time.

20220915133703

Built-in adjustable electric back-up from 3KW to 9KW, faster heating for your room when there is requirement, also more stable heating when weather is extremely cold.

202209151337032

Use SWEP high-quality plate heat exchanger to provide higher efficiency and more suitable for the use of anti-icing fluid.

202209151337034

 

Hot Tags: r32 inverter heat pump, China r32 inverter heat pump manufacturers, suppliers, factory, Hvac Inverter Heat Pump, inverter heat pump, R32 Inverter Heat Pump, Split Heat Pump, Split R32 DC Inverter Air To Water Heat Pump, Whole House Inverter Heat Pump

Send Inquiry