Our R32 split inverter heat pump adopts a DC inverter system. Optimized energy efficiency control software allows the unit to run with maximum energy savings. This R32 heat pump can deliver hot water up to 60°C and provides space heating & cooling for buildings. It operates reliably within an ambient temperature range of -25°C to 43°C.We have supplied units to numerous European markets. Particularly suited for low-climate regions including Eastern and Northern Europe, our split-type inverter heat pump effectively lowers the risk of freezing.
Dc Heat Pump Parameters
|
K-Thermal DC Inverter air to water heat pump for Heating & Cooling & Hot Water (Split type, R32 ) |
||||||
|
Model |
DCI03PS-H3DS |
DCI05PS-H5DS |
DCI06PS-H5DS |
DCI08P-H8DS |
||
|
Power supply |
V/ Hz |
220V/50Hz |
380V/50Hz |
|||
|
Dry/Wet bulb: 7/6℃; Water inlet/outlet: 35/40℃ |
||||||
|
Heating capacity |
kW |
10.50 |
14.71 |
16.23 |
20.20 |
|
|
Input power |
kW |
2.15 |
3.13 |
3.51 |
4.33 |
|
|
COP |
/ |
4.88 |
4.70 |
4.63 |
4.66 |
|
|
Dry/Wet bulb: 7/6℃; Water inlet/outlet: 45/50℃ |
||||||
|
Heating capacity |
kW |
10.60 |
14.89 |
15.97 |
20.00 |
|
|
Input power |
kW |
2.79 |
4.01 |
4.63 |
6.05 |
|
|
COP |
/ |
3.80 |
3.71 |
3.45 |
3.31 |
|
|
Dry/Wet bulb: 7/6℃; Water inlet/outlet: 47/55℃ |
||||||
|
Heating capacity |
kW |
10.15 |
13.60 |
15.25 |
19.64 |
|
|
Input power |
kW |
3.39 |
4.26 |
5.00 |
6.34 |
|
|
COP |
/ |
2.99 |
3.19 |
3.05 |
3.10 |
|
|
Dry/Wet bulb: -7/-8℃; Water inlet/outlet: 30/35℃ |
||||||
|
Heating capacity |
kW |
7.58 |
12.12 |
14.48 |
16.51 |
|
|
Input power |
kW |
2.32 |
3.66 |
4.52 |
5.25 |
|
|
COP |
/ |
3.27 |
3.32 |
3.20 |
3.15 |
|
|
Dry/Wet bulb: -20/-21℃; Water inlet/outlet: 30/35℃ |
||||||
|
Heating capacity |
kW |
4.51 |
7.32 |
8.47 |
10.45 |
|
|
Input power |
kW |
2.19 |
3.26 |
3.85 |
4.85 |
|
|
COP |
/ |
2.06 |
2.25 |
2.20 |
2.16 |
|
|
Dry/Wet bulb: 35/24℃; Water inlet/outlet: 23/18℃ |
||||||
|
Cooling capacity |
kW |
10.40 |
14.93 |
16.17 |
20.17 |
|
|
Input power |
kW |
2.35 |
3.51 |
4.10 |
5.03 |
|
|
EER |
/ |
4.43 |
4.25 |
3.94 |
4.01 |
|
|
Dry/Wet bulb: 35/24℃; Water inlet/outlet: 12/7℃ |
||||||
|
Cooling capacity |
kW |
8.46 |
12.83 |
14.06 |
18.10 |
|
|
Input power |
kW |
2.88 |
4.49 |
4.97 |
6.43 |
|
|
EER |
/ |
2.93 |
2.86 |
2.83 |
2.81 |
|
|
Seasonal Heating Energy Efficiency Rating |
LWT at 35℃ |
A+++ |
A+++ |
A+++ |
A+++ |
|
|
LWT at 55℃ |
A++ |
A++ |
A++ |
A++ |
||
|
SCOP |
LWT at 35℃ |
4.55 |
4.64 |
4.70 |
4.64 |
|
|
LWT at 55℃ |
3.55 |
3.58 |
3.65 |
3.43 |
||
|
SEER |
LWT at 7℃ |
4.66 |
4.67 |
4.62 |
4.65 |
|
|
LWT at 18℃ |
6.58 |
6.85 |
6.74 |
6.76 |
||
|
Max. Current |
A |
14.10+13.60+13.60+13.60 |
30+13.60+13.60+13.60 |
30+13.60+13.60+13.60 |
15+13.60+13.60+13.60 |
|
|
Rated Current |
A |
10+13.60+13.60+13.60 |
14+13.60+13.60+13.60 |
15+13.60+13.60+13.60 |
8+13.60+13.60+13.60 |
|
|
Water pressure drop |
kPa |
40.00 |
42.00 |
44.00 |
46.00 |
|
|
System pressure |
Mpa |
1/4.15 |
||||
|
Refrigerant |
Type |
R32 |
R32 |
R32 |
R32 |
|
|
Quantity |
kg |
2.50 |
2.90 |
3.50 |
4.00 |
|
|
GWP value |
675.00 |
675.00 |
675.00 |
675.00 |
||
|
Equivalent CO2 |
Ton |
1.69 |
1.96 |
2.36 |
2.70 |
|
|
Fan motor |
Type |
DC INVERTER |
||||
|
Quantity |
1.00 |
2.00 |
2.00 |
2.00 |
||
|
Noise level(Outdoor unit) |
dB(A) |
57.00 |
62.00 |
62.00 |
68.00 |
|
|
Noise level(Indoor unit) |
dB(A) |
35.00 |
35.00 |
35.00 |
35.00 |
|
|
Waterproof level |
IPX4 |
|||||
|
Refrigerant pipe between indoor and outdoor unit |
Gas pipe |
mm |
φ15.88 |
φ15.88 |
φ15.88 |
φ19 |
|
Liquid pipe |
mm |
φ9.52 |
φ9.52 |
φ9.52 |
φ9.52 |
|
|
Water pipe connection |
Inlet |
mm |
DN25 |
DN25 |
DN25 |
DN32 |
|
Outlet |
mm |
DN25 |
DN25 |
DN25 |
DN32 |
|
|
Outdoor unit dimensions |
mm |
1160x490x860 |
1160x490x1260 |
1160x490x1260 |
1160x490x1568 |
|
|
Outdoor unit pacakge dimensions |
mm |
1195x500x1010 |
1195x500x1410 |
1195x500x1410 |
1195x500x1718 |
|
|
Indoor unit dimensions |
mm |
530*770*340 |
530*770*340 |
530*770*340 |
530*770*340 |
|
|
Indoor unit pacakge dimensions |
mm |
570*790*400 |
570*790*400 |
570*790*400 |
570*790*400 |
|
|
Outdoor unit Net Weight |
kg |
60 |
90 |
100 |
120 |
|
|
Indoor unit Net Weight |
kg |
33.5 |
35 |
36 |
38 |
|
|
Loading(20GP/40HQ) |
Pcs |
32/76 |
21/44 |
21/44 |
21/44 |
|
|
The above parameters may have some differences from the final product because of products updating, so above information is not the provision of any business contract. Please refer to final product label when buy, or refer to us for any information. Our company keeps the right to interpret. |
||||||

Adopting the new R32 refrigerant with zero ODP and a GWP value of 675, our units help cut greenhouse gas emissions for sustainable development.
Our heat pumps support WiFi connectivity. You can conveniently control the unit via our custom-developed dedicated App.


High-precision electronic expansion valve: The unit adopts an electronic expansion valve with 500-step regulation. It precisely adjusts the superheat degree to ensure the system operates with high efficiency.
Energy efficiency class A++ for heating mode at a supply water temperature of 55°C.

Hot Tags: r32 inverter air source heat pump, China r32 inverter air source heat pump manufacturers, suppliers, factory, DC Inverter, Hvac Inverter Heat Pump, R32 Air To Water, R32 Inverter Heat Pump, Split Heat Pump, Whole House Inverter Heat Pump