This High Temperature Heat Pump adopts well-known brand core components, equipped with either Panasonic compressors paired with R134a refrigerant, or Copeland compressors with R134a refrigerant. Customization is available with 304/316 stainless steel housing as an option. Our Commercial High Temperature Heat Pump System is ideal for large buildings and engineering projects, including schools, hospitals, canteens, hotels and other venues. This commercial high-temperature heat pump water heater can deliver hot water up to 80°C and features a maximum heating capacity of 154kW. Its control system supports master-slave connection (up to 16 units), Modbus communication, with Wi-Fi connectivity offered as an optional function.
The high-temperature heat pump is fitted with reputable components: Panasonic compressor + R134a refrigerant or Copeland compressor + R134a refrigerant. 304/316 stainless steel casing can be customized upon request.
Designed for large buildings and projects such as schools, hospitals, restaurants and hotels, this commercial high-temperature heat pump water heater achieves a maximum outlet water temperature of 80°C and a peak heating capacity of 154kW. The controller enables master-slave control (supports up to 16 units) and Modbus communication; Wi-Fi function is available as an optional extra.

Volcano series (High temperature air source heat pump water heater circulation type)

 

HT3Ps-E3

HT5sP-E5

HT3P-E3

HT5P-E5

HT7P-E7

HT10P-E10

HT14P-E14

HT20P-E20

HT24P-E20

HT30P-E20

HT48P-C96

HT60P-C96

Rated heating capacity

kW

8.2

13.5

8.2

13.5

17.8

26.1

34.7

55.2

64.3

78.5

129.5

153.7

Rated input power

kW

2.42

3.98

2.42

3.95

5.26

7.65

10.21

16.32

19.13

23.56

38.09

45.88

Rated input current

A

10.58

17.56

4.58

7.52

9.99

14.55

19.35

30.95

36.33

44.71

72.34

87.14

Maximum input power

kW

3.14

5.17

3.14

5.13

6.84

9.95

13.27

21.22

24.88

30.63

47.62

57.36

Maximum input current

A

14.01

23.23

5.95

9.75

13.02

19.13

24.98

40.25

46.88

57.96

90.44

108.94

Performance coefficient (COP)

/

3.39

3.39

3.39

3.42

3.38

3.41

3.40

3.38

3.36

3.33

3.40

3.35

Rated hot water output temp.

℃

75

Maximum hot water output temp.

℃

80

Rated hot water produce capacity

△t40

L/H

175.7

289.3

175.7

289.3

381.4

559.3

743.6

1182.9

1377.9

1682.1

2795.0

3440.0

△t60

L/H

117.1

192.9

117.1

192.9

254.3

372.9

495.7

788.6

918.6

1121.4

1863.3

2293.4

Power supply

1N 220V/50Hz

3N 380V/50Hz

Compressor

Type

Hermetic scroll type

Start Mode

Directly start (Soft start for option)

Quantity

Set

1

1

1

1

1

2

2

4

4

4

4

4

Water side heat exchanger

Type

Shell & coil (tube) heat exchanger

Water flow

m3/h

1.4

2.3

1.4

2.3

3.1

4.5

6.0

9.5

11.2

13.8

22.4

27.6

Water Pressure Drop

kPa

≤45

≤53

<50

<55

<57

<60

<70

<70

<72

<72

<75

<75

Pipe size

mm

DN20

DN25

DN20

DN25

DN25

DN32

DN32

DN50

DN50

DN50

DN80

DN80

Protections

1. High pressure and low pressure protection
2. Anti-freezing protection
3. High temperature protection
4. Too big of the water temperature difference for outlet and inlet protection
5. Overload protection
6. Lack phase protection
7. Reverse phase protection, etc..

Refrigerant

Type

R134a

Throttle Type

Electronic expansion valve

Quantity

kg

1.9

3.3

1.9

3.3

4.3

2.8×2

4.1×2

3.2×4

3.8×4

4.6x4

7.6×4

9.2x4

Noise

DB(A)

≤55

≤63

≤55

≤63

≤65

≤68

≤68

≤70

≤70

≤72

≤74

≤75

Dimension

mm

700×680×875

820×695×1060

700×680×875

820×695×1060

820×695×1360

1502×750×1060

1502×750×1360

1995×1165×1105

1995×1165×1105

1995×1165×1105

2000×2050×1980

2000×2050×1980

Net Weight

kg

110

160

110

160

190

255

410

600

755

855

1250

1620

Testing conditions:

1. Application side initial water temperature: 15℃, end temperature 75℃, max. temperature 80℃.

2. Ambient temperature dry bulb 20℃, wet bulb 15℃.

The above parameters are based on Refrigearnt R134a, for parameters based on other refrigerant please contact us.

The above parameters may have some differences from the final product because of products updating, so above information is not the provision of any business contract. Please refer to final product label when buy, or refer to us for any information. Our company keeps the right to interpret.

 

Our Projects

Architectural design & planning cepteur sint occaecat cupidatat proident

 

eco-friendly

Low-GWP R134a refrigerant delivers superior environmental performance. Its lower working pressure improves safety while allowing the unit to reach higher outlet water temperatures.

WIFI

Wi-Fi function is available as an option. You can remotely control the heat pump anytime via the stable mobile App on your smartphone.

Modbus

Fitted with an RS485 interface and supporting the Modbus communication protocol, the unit can be easily connected to a BMS system and enables modular control of multiple units.

 

80C

Delivers a maximum outlet water temperature of 80°C.

V-SHAPE

Improved Energy Efficiency

 
Thanks to the V-shaped Φ7mm evaporator coils and blue surface coating, efficiency rises by 20%, perfectly suited for seaside cities.

Hot Tags: high temperature heat pump, high temperature heat pump manufacturers in China, suppliers, factory, air to air heat pumps for commercial buildings, air to water heat pump, commercial air source heat pump, commercial heat pump system, commercial hot water heat pump water heater, high temperature heat pump.

 

Hot Tags: high-temperature air source heat pump, China high-temperature air source heat pump manufacturers, suppliers, factory

Send Inquiry